Abstract
Respiratory droplets are a primary source of airborne particulate matter in indoor environments, particularly in close-contact settings such as hairdressing salons, where prolonged face-to-face interactions and ventilation-driven airflow patterns significantly increase exposure risk. Although adequate ventilation is essential, ventilation rate alone cannot indicate whether the resulting airflow removes cough-generated droplets or redistributes them between occupied regions. Therefore, the present study was designed to investigate airflow behaviour and cough-generated droplet transport in a representative hairdressing salon using a validated three-dimensional Computational Fluid Dynamics–Discrete Phase Model (CFD–DPM) framework. The airflow field was resolved using the k–ω SST turbulence model, and droplets ranging from 3 μm to 750 μm were simulated under both single- and multiple-cough scenarios. A systematic parametric analysis was conducted to determine how diffuser supply angles of 30°, 45°, and 60° and alternative air-conditioner locations affected airflow organisation, droplet residence, and potential cross-occupant exposure. The baseline configuration was found to produce a jet-dominated but spatially non-uniform airflow characterised by recirculation zones, an elevated mean age of air, and prolonged particle residence within occupied regions. Fine and intermediate droplets (3–112.5 μm) remained airborne and closely followed the airflow structures, resulting in extended dispersion and potential cross-occupant exposure, whereas larger droplets settled rapidly near the source. Among the diffuser orientations investigated, the 45° supply angle provided the most balanced airflow distribution and ventilation effectiveness by reducing stagnant and recirculating regions. Repositioning the air conditioner and reorienting the supplied airflow transformed the flow from a recirculation-dominated regime into a coherent directional transport pattern, reducing the representative particle population in the identified high-risk zones by approximately 50% at 0.50 s and 38% at 0.80 s. These findings show that contaminant-control performance depends not only on ventilation rate but also on the direction and spatial organisation of the supplied airflow. The principal contribution of this study is the quantitative linkage of diffuser orientation and air-conditioner placement with size-dependent droplet transport and zone-specific exposure under the same ventilation operating conditions. This study provides quantitative, design-oriented guidance for improving ventilation strategies in hairdressing salons and similar close-contact service environments and establishes a foundation for future integration with artificial-intelligence-assisted optimisation frameworks for infection-resilient building design.
| Original language | English |
|---|---|
| Article number | 117592 |
| Journal | Journal of Building Engineering |
| Volume | 133 |
| DOIs | |
| Publication status | Published - 1 Dec 2026 |
Keywords
- Computational fluid dynamics (CFD)
- Discrete phase model (DPM)
- Hairdressing salons
- Respiratory droplet transport
- Ventilation design optimisation
Fingerprint
Dive into the research topics of 'Ventilation design optimisation for mitigating airborne droplet transport and exposure in hairdressing salons using CFD–DPM'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver