Skip to main navigation Skip to search Skip to main content

Ultrasensitive and selective impedance paper-based analytical device through Dual-C imprinted sensor for determination of carcinoembryonic antigen and C-reactive protein

  • Kanpitcha Somnet
  • , Surasak Wanram
  • , Sanoe Chairam
  • , Purim Jarujamrus
  • , Duangjai Nacapricha
  • , Peter A. Lieberzeit
  • , Maliwan Amatatongchai
  • Ubon Ratchathani University
  • Mahidol University
  • Flow-Innovation Research for Science and Technology Laboratories
  • University of Vienna

Research output: Contribution to journal › Article › peer-review

7 Citations (Scopus)

Abstract

Carcinoembryonic antigen (CEA) and C-reactive protein (CRP) are biomacromolecules known as cancer and inflammatory markers. Thus, they play a crucial role in early cancer diagnosis, post-treatment recurrence detection, and tumor risk assessment. This paper describes the development of an ultrasensitive and selective imprinted paper-based analytical device (PAD) as impedance sensor for determination of CEA and CRP in serum samples for point-of-care testing (POCT). They combine a core comprising of silica nanospheres decorated with silver nanoparticles (SiO2@AgNPs) coated with molecularly imprinted polymers (MIPs) for CEA and CRP as shells. CEA-MIP and CRP-MIP were successful coated on the core via self-assembly of N-acetyl-l-cysteine (NAC) followed by building up recognition sites in iminodiacetic acid/ethylene glycol dimethacrylate (IDA/EGDMA) polymer. We constructed a selective and compact imprinted PAD based on a SiO2@AgNPs@MIP-CEA- and SiO2@AgNPs@MIP-CRP-modified graphene electrode, a so-called Dual-C sensor. The resulting twin voltammetric cells to detect CEA and CRP use foldable hydrophobic back-up sheets acting as reservoirs. The advantages of this approach include straightforward manufacturing with highly reproducibility, quick assembly, and good physical durability. The Dual-C sensor revealed excellent linear dynamic ranges of 0.0001 to 10 ng mL−1 for both CEA and CRP, which covers on the concentration ranges of clinical interest for both analytes. Furthermore, the system shows high accuracy and precision, with no evidence of interference from serum samples.

Original languageEnglish
Article number112
JournalMicrochimica Acta
Volume192
Issue number2
DOIs
Publication statusPublished - Feb 2025
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being
  2. SDG 9 - Industry, Innovation, and Infrastructure
    SDG 9 Industry, Innovation, and Infrastructure

Keywords

  • C-reactive protein
  • Carcinoembryonic antigen
  • Dual imprinted sensor
  • Molecularly imprinted polymers (MIP)
  • Point-of-care testing (POCT)

Fingerprint

Dive into the research topics of 'Ultrasensitive and selective impedance paper-based analytical device through Dual-C imprinted sensor for determination of carcinoembryonic antigen and C-reactive protein'. Together they form a unique fingerprint.

Cite this