T1 - The effect of hypothermic machine perfusion and cold storage for kidney preservation
AU - Chusri, Yanee
AU - Gesprasert, Goragoch
AU - Khienwad, Thananya
AU - Naiyanate, Phornphop
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2017/12/19
Y1 - 2017/12/19
N2 - Currently, two principles of the kidney preservation (hypothermic machine perfusion; HMP and cold storage; CS) are generally used in kidney transplantation. Both HMP and CS are developed base on the suitable conditions that can maintain the kidney function. In this study, the vascular impedance of kidney was investigated. This experiment aims to comparison the impedance between HMP and CS methods by using a kidney of pig from slaughterhouse. The protocol of impedance estimation, after the kidney was remove from pig (mixed breed pigs), it was gravity flushing to wash blood out. After that, each kidneys were measured impedance before the preservation method. For HMP method, other 3 kidneys were preserved with continuous flow of Euro's Collins preservation solution that maintain pressure around 40 ± 5 mmHg at temperature 4-6 °C for 24 hours. For CS method, 3 kidneys were kept in chamber that filled with Euro's Collins preservation solution at temperature 4-6 °C for 24 hours. After 24 hours, impedance estimation was performed. Results: from the first impedance estimation, both HMP and CS impedances were 0.957±0.95 and 1.024±0.05 mmHg min/ml, respectively. After 24 hours, the impedance of HMP method were higher than CS method (1.059±0.09 and 1.028±0.009 respectively). Conclusion, the kidney preservation using HMP show higher impedance than CS method because the autoregulation in the kidney vascular system that effect to the metabolite phenomenon. Therefore, the HMP preservation can preserving kidneys better than CS preservation.
AB - Currently, two principles of the kidney preservation (hypothermic machine perfusion; HMP and cold storage; CS) are generally used in kidney transplantation. Both HMP and CS are developed base on the suitable conditions that can maintain the kidney function. In this study, the vascular impedance of kidney was investigated. This experiment aims to comparison the impedance between HMP and CS methods by using a kidney of pig from slaughterhouse. The protocol of impedance estimation, after the kidney was remove from pig (mixed breed pigs), it was gravity flushing to wash blood out. After that, each kidneys were measured impedance before the preservation method. For HMP method, other 3 kidneys were preserved with continuous flow of Euro's Collins preservation solution that maintain pressure around 40 ± 5 mmHg at temperature 4-6 °C for 24 hours. For CS method, 3 kidneys were kept in chamber that filled with Euro's Collins preservation solution at temperature 4-6 °C for 24 hours. After 24 hours, impedance estimation was performed. Results: from the first impedance estimation, both HMP and CS impedances were 0.957±0.95 and 1.024±0.05 mmHg min/ml, respectively. After 24 hours, the impedance of HMP method were higher than CS method (1.059±0.09 and 1.028±0.009 respectively). Conclusion, the kidney preservation using HMP show higher impedance than CS method because the autoregulation in the kidney vascular system that effect to the metabolite phenomenon. Therefore, the HMP preservation can preserving kidneys better than CS preservation.
KW - Hypothermic machine perfusion
KW - cold storage
KW - impedance
KW - kidney preservation
UR - https://www.scopus.com/pages/publications/85046337275
U2 - 10.1109/BMEiCON.2017.8229128
DO - 10.1109/BMEiCON.2017.8229128
M3 - Conference contribution
AN - SCOPUS:85046337275
T3 - BMEiCON 2017 - 10th Biomedical Engineering International Conference
SP - 1
EP - 4
BT - BMEiCON 2017 - 10th Biomedical Engineering International Conference
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 10th Biomedical Engineering International Conference, BMEiCON 2017
Y2 - 31 August 2017 through 2 September 2017
ER -