TY - GEN
T1 - The effect of electrical distribution on agar plate using ring electrodes
AU - Pornprasit, Chatpech
AU - Rattanasomrerk, Saendee
AU - Kiratisin, Pattarachai
AU - Thaipisuttikul, Iyarit
AU - Naiyanetr, Phornphop
N1 - Publisher Copyright:
© 2019 IEEE.
PY - 2019/11
Y1 - 2019/11
N2 - The experimental set up for studying the effects of electric current on cell activities in vitro that always be performed is based on straight parallel electrodes which can generate a specific magnitude of current density on the cultured cells. This depends on input voltage and the gap between the electrodes. With this method, lots of set-ups for trial error are required to find the threshold of any effects. This study suggested a novel technique which used 2 ring electrodes (inner electrode and outer electrode with 5.50 and 40.65 mm radius respectively) to spread out the current radially and cause the current density near the inner electrode to be more intense than the outer electrode. A simple equation was provided to approximate the current density at any point on the surface of the agar between the electrodes. This equation was verified by comparing the calculated result to the result from the finite element method and to the result from testing on a real blood agar. By comparing to the result from the finite element method, there is a mean error of the current density and voltage difference for 10-35 mm and 8-30 mm radius about 1.7341 ± 0.9868% and 2.9563 ± 1.8867% respectively. By comparing to the result from testing on a real blood agar, there is a mean error of the voltage difference for 10-20 mm radius about 3.78±1.70%. With this new technique, the researchers just locate the area on the petri dish that has cellular changes and calculate the magnitude of the current density that is linked to the results by the provided equation. This method can waste fewer set-ups for trial error and shorten the length of the study.
AB - The experimental set up for studying the effects of electric current on cell activities in vitro that always be performed is based on straight parallel electrodes which can generate a specific magnitude of current density on the cultured cells. This depends on input voltage and the gap between the electrodes. With this method, lots of set-ups for trial error are required to find the threshold of any effects. This study suggested a novel technique which used 2 ring electrodes (inner electrode and outer electrode with 5.50 and 40.65 mm radius respectively) to spread out the current radially and cause the current density near the inner electrode to be more intense than the outer electrode. A simple equation was provided to approximate the current density at any point on the surface of the agar between the electrodes. This equation was verified by comparing the calculated result to the result from the finite element method and to the result from testing on a real blood agar. By comparing to the result from the finite element method, there is a mean error of the current density and voltage difference for 10-35 mm and 8-30 mm radius about 1.7341 ± 0.9868% and 2.9563 ± 1.8867% respectively. By comparing to the result from testing on a real blood agar, there is a mean error of the voltage difference for 10-20 mm radius about 3.78±1.70%. With this new technique, the researchers just locate the area on the petri dish that has cellular changes and calculate the magnitude of the current density that is linked to the results by the provided equation. This method can waste fewer set-ups for trial error and shorten the length of the study.
KW - bioelectric effect
KW - electric current density
KW - petri dish
UR - https://www.scopus.com/pages/publications/85080057418
U2 - 10.1109/BMEiCON47515.2019.8990305
DO - 10.1109/BMEiCON47515.2019.8990305
M3 - Conference contribution
AN - SCOPUS:85080057418
T3 - BMEiCON 2019 - 12th Biomedical Engineering International Conference
BT - BMEiCON 2019 - 12th Biomedical Engineering International Conference
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 12th Biomedical Engineering International Conference, BMEiCON 2019
Y2 - 19 November 2019 through 22 November 2019
ER -