Skip to main navigation Skip to search Skip to main content

The effect of baricity of intrathecal bupivacaine for elective cesarean delivery on maternal cardiac output: a randomized study

  • Siriraj Hospital

Research output: Contribution to journal › Article › peer-review

3 Citations (Scopus)

Abstract

Background: Hemodynamic instability during spinal anesthesia for cesarean delivery is associated with adverse maternal and fetal outcomes. Plain and hyperbaric bupivacaine are commonly used for cesarean delivery, however, their distinctive pharmacologic properties may affect maternal hemodynamic profiles differently. The aim of this study was to compare hemodynamic profiles using a suprasternal Doppler cardiac output (CO) monitor in healthy term parturients randomized to receive plain or hyperbaric bupivacaine for cesarean delivery. Methods: One hundred-and-sixty-eight healthy parturients scheduled for elective cesarean delivery were randomly assigned to receive 10.9 mg of intrathecal 0.5% plain or hyperbaric bupivacaine, both with 0.2 mg morphine. The primary outcome was CO change after spinal anesthesia. Secondary outcomes were the incidence of hypotension, vasopressor use, and conversion to general anesthesia. Results: The mean (±SD) CO at baseline, 1 min and 5 min after spinal anesthesia, and after placental delivery was 4.6 ± 1.2, 5.4 ± 1.3, 5.1 ± 1.4, and 6.4 ± 1.7 L/min in the plain bupivacaine, and 4.5 ± 1.1, 5.2 ± 1.3, 4.9 ± 1.3, and 6.2 ± 1.9 L/min in the hyperbaric bupivacaine group. There were no significant differences in CO, mean arterial pressure, or systemic vascular resistance. Incidences of hypotension, vasopressor and supplemental analgesic use, and conversion to general anesthesia, were not different between groups. Conclusions: Cardiac output changes after plain or hyperbaric bupivacaine were not different in term parturients undergoing spinal anesthesia for cesarean delivery. Further studies comparing block quality and the rate of conversion to general anesthesia are required.

Original languageEnglish
Pages (from-to)61-66
Number of pages6
JournalInternational Journal of Obstetric Anesthesia
Volume45
DOIs
Publication statusPublished - Feb 2021

Keywords

  • Bupivacaine baricity
  • Cardiac output
  • Cesarean delivery
  • Maternal hemodynamic
  • Spinal anesthesia

Fingerprint

Dive into the research topics of 'The effect of baricity of intrathecal bupivacaine for elective cesarean delivery on maternal cardiac output: a randomized study'. Together they form a unique fingerprint.

Cite this