Skip to main navigation Skip to search Skip to main content

Simultaneous and direct determination of urea and creatinine in human urine using a cost-effective flow injection system equipped with in-house contactless conductivity detector and LED colorimeter

  • Sumonmarn Chaneam
  • , Kamparnart Kaewyai
  • , Thitirat Mantim
  • , Rasamee Chaisuksant
  • , Prapin Wilairat
  • , Duangjai Nacapricha
  • Silpakorn University
  • Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs)
  • Mahidol University
  • Srinakharinwirot University
  • Mahidol University

Research output: Contribution to journal › Article › peer-review

30 Citations (Scopus)

Abstract

This work presents a cost-effective and simple flow injection analysis (FIA) system for simultaneous and direct determination of urea and creatinine in human urine. The FIA system comprises two in-house detectors, a contactless conductivity detector and a light emitting diode (LED) detector. The contactless detector was built as a flow-through detection cell with axial electrodes, commonly known as capacitively coupled contactless conductivity detector (C4D) and the diode detector was fabricated based on the concept of paired emitter detector diodes (PEDD). With appropriate dilution of urine, the sample is directly injected into a stream of glycine-NaOH buffer pH 8.8 (the gas donor stream) and is carried by the carrier through a urease minicolumn for on-line enzymatic hydrolysis. The generated NH3 diffuses from the carrier stream through a porous polytetrafluoroethylene (PTFE) membrane into a stream of deionized water (the acceptor stream) leading to an increase in the signal at the C4D due to the NH3 dissolution in the water. In this system, creatinine is determined based on the Jaffé reaction by merging a stream of alkaline picrate with the gas donor stream. The change in color is detected using the PEDD equipped with two green LEDs. Under the optimum condition, the linear range of urea and creatinine were 30–240 mg L−1 and 10–500 mg L−1, with limits of detection of 9.0 mg L−1 and 0.9 mg L−1, respectively. The proposed system provides satisfactorily good precision (RSD < 3%), with sample throughput of 31 sample h−1 for the two analytes. The FIA system tolerates potential interference commonly found in human urine. The system was successfully applied and validated with selected reference methods.

Original languageEnglish
Pages (from-to)54-61
Number of pages8
JournalAnalytica Chimica Acta
Volume1073
DOIs
Publication statusPublished - 27 Sept 2019
Externally publishedYes

Keywords

  • Capacitively coupled contactless conductivity detector (C4D)
  • Creatinine
  • Flow injection analysis (FIA)
  • Paired emitter detector diodes (PEDD)
  • Urea
  • Urine

Fingerprint

Dive into the research topics of 'Simultaneous and direct determination of urea and creatinine in human urine using a cost-effective flow injection system equipped with in-house contactless conductivity detector and LED colorimeter'. Together they form a unique fingerprint.

Cite this