Skip to main navigation Skip to search Skip to main content

Reliability assessment of thick high strength pipelines with corrosion defects

  • U. Bhardwaj
  • , A. P. Teixeira
  • , C. Guedes Soares
  • , Md Samdani Azad
  • , W. Punurai
  • , P. Asavadorndeja
  • Instituto Superior Técnico
  • Mahidol University
  • Synterra Co. Ltd

Research output: Contribution to journal › Article › peer-review

58 Citations (Scopus)

Abstract

This paper assesses the reliability of thick, high strength corroded pipelines subjected to internal pressure by first order reliability algorithms and Monte Carlo simulation methods. First, the predictions of different burst strength models, including a new prediction model for thick high strength pipelines are compared with experimental results. Model uncertainty factors are derived for intact and corroded pipelines to calibrate and introduce the uncertainties on the models used in the prediction of structural reliability. The uncertainty associated with model uncertainty factors is addressed and the best fitting distribution is identified. Extensive reliability and sensitivity analyses are carried out on intact and corroded pipes with calibrated burst strength models. Through sensitivity analyses performed for increasing levels of corrosion defects, the influence of basic parameters on the burst strength of corroded pipelines is characterized. The results demonstrate that the model uncertainty factors and the depth of corrosion are relatively important variables for corroded pipelines. The results obtained through reliability assessment are compared with that obtained by the strength model proposed in the RAMPIPE guidelines.

Original languageEnglish
Article number103982
JournalInternational Journal of Pressure Vessels and Piping
Volume177
DOIs
Publication statusPublished - Nov 2019

Keywords

  • Corroded pipeline
  • Model uncertainty factor
  • Reliability
  • Sensitivity analysis
  • Thick high strength pipeline

Fingerprint

Dive into the research topics of 'Reliability assessment of thick high strength pipelines with corrosion defects'. Together they form a unique fingerprint.