Abstract
A retrospective study of 533 eyes, which underwent complete pre-operative evaluation for refractive surgery, was done. Regression Analysis was performed to find the correlation between corneal thickness and level of myopia and between corneal thickness and corneal curvature. There was statistically significant correlation between corneal thickness and level of myopia (p = 0.039) and also in corneal thickness and corneal curvature (p = 0.04). No clinical correlation was demonstrated (R2 = 0.014 and R2 = 0.0153, respectively). There was no clinical correlation between corneal thickness and level of myopia and also between corneal thickness and corneal curvature.
| Original language | English |
|---|---|
| Pages (from-to) | 162-166 |
| Number of pages | 5 |
| Journal | Journal of the Medical Association of Thailand |
| Volume | 85 |
| Issue number | 2 |
| Publication status | Published - Feb 2002 |
Keywords
- Corneal curvature
- Corneal thickness
- Level of myopia
Fingerprint
Dive into the research topics of 'Relationship between corneal thickness and level of myopia'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver