Abstract
The cryptococcal antigen lateral flow assay (CrAg LFA) was evaluated for the diagnosis of cryptococcosis in HIV-negative patients. The sensitivity was excellent, suggesting that this assay can replace conventional testing based on latex agglutination (LA). CrAg LFA and LA titers were correlated but were not directly comparable, with implications for conversion between assays.
| Original language | English |
|---|---|
| Pages (from-to) | 460-463 |
| Number of pages | 4 |
| Journal | Journal of Clinical Microbiology |
| Volume | 54 |
| Issue number | 2 |
| DOIs | |
| Publication status | Published - Feb 2016 |
| Externally published | Yes |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Fingerprint
Dive into the research topics of 'Performance of the cryptococcal antigen lateral flow assay in non-HIV-related cryptococcosis'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver