Skip to main navigation Skip to search Skip to main content

Measures of Serum Markers HbA1c, HOMA-IR, HOMA-β, QUICKI and G/I Ratio as Predictors of Abnormal Glucose Tolerance Among Thai Women with Polycystic Ovary Syndrome

  • Faculty of Medicine, Thammasat University
  • Siriraj Hospital

Research output: Contribution to journal › Article › peer-review

11 Citations (Scopus)

Abstract

Background/Objectives: Polycystic ovary syndrome (PCOS) is a prevalent endocrine disorder affecting women of reproductive age. It is associated with glucose intolerance, insulin resistance and diabetes mellitus. The oral glucose tolerance test (OGTT) is commonly employed to detect glucose intolerance, but it can be inconvenient and time-consuming. We aimed to evaluate the precision of haemoglobin A1c (HbA1c) and other serum markers in predicting abnormal glucose tolerance (AGT). Methods: This diagnostic study involved 121 PCOS women who attended the Gynaecologic Endocrinology Unit at Siriraj Hospital. Patients underwent assessments for weight, height, waist circumference, modified Ferriman–Gallwey score and acanthosis nigricans. Blood samples were collected to measure fasting glucose and insulin levels after a 75-gram oral OGTT, fasting insulin level, HbA1c, lipid profile, androgen profile and complete blood count. Homeostasis model assessment of insulin resistance (HOMA-IR), homeostasis model assessment of beta-cell function (HOMA-β), quantitative insulin sensitivity check index (QUICKI) and fasting glucose-to-insulin ratio (G/I ratio) were calculated. The sensitivity, specificity and accuracy of these serum markers were compared. Results: The prevalence of AGT was 24.8%. The area under the receiver operating characteristic curve for HbA1c in detecting AGT was 0.656, while HOMA-IR, HOMA-β, QUICKI and the G/I ratio had values of 0.817, 0.737, 0.817 and 0.77, respectively. The G/I ratio cut-off point of 6% demonstrated a sensitivity of 73.3%, specificity of 74.7%, positive predictive value of 48.9%, negative predictive value of 89.5% and accuracy of 74.4%. Conclusions: The G/I ratio is the most accurate compared to other serum markers in detecting AGT among Thai women with PCOS.

Original languageEnglish
Article number1452
JournalJournal of Clinical Medicine
Volume14
Issue number5
DOIs
Publication statusPublished - Mar 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • PCOS
  • glucose intolerance
  • serum markers

Fingerprint

Dive into the research topics of 'Measures of Serum Markers HbA1c, HOMA-IR, HOMA-β, QUICKI and G/I Ratio as Predictors of Abnormal Glucose Tolerance Among Thai Women with Polycystic Ovary Syndrome'. Together they form a unique fingerprint.

Cite this