Abstract
Forty-eight matched pairs of osteoarthritic knees from patients who underwent primary total knee arthroplasty with a round-on-round, Apollo Knee System were studied to evaluate the outcome between all-polyethylene and metal-backed tibial components. Patients were matched for patient factors, preoperative deformities, cruciate salvage or sacrifice, and surgical technique. At the last follow-up (average, 38.4 months), there was no statistically significant difference in terms of knee scores, patient self-assessment, and radiographic outcomes. No component required revision, and no revisions were pending. Maintenance of these results over time would project into better long-term success for all-polyethylene tibial components because of the amount of wear and osteolysis with current modular metal-backed tibial components. We advocate the use of a more cost-effective all-polyethylene tibial component in elderly patients (>70 years old) who are not likely to need the versatility of exchange of a modular polyethylene insert because of wear.
| Original language | English |
|---|---|
| Pages (from-to) | 689-696 |
| Number of pages | 8 |
| Journal | Journal of Arthroplasty |
| Volume | 16 |
| Issue number | 6 |
| DOIs | |
| Publication status | Published - 2001 |
| Externally published | Yes |
Keywords
- All-polyethylene
- Knee arthroplasty
- Matched pair
- Metal-backed
- Tibial component
Fingerprint
Dive into the research topics of 'Matched-pair analysis of all-polyethylene versus metal-backed tibial components'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver