High-output pacing in mapping of postinfarction ventricular tachycardia

  • Jean François Sarrazin
  • , Michael Kuehne
  • , Darryl Wells
  • , Nagib Chalfoun
  • , Thomas Crawford
  • , Warangkna Boonyapisit
  • , Eric Good
  • , Aman Chugh
  • , Hakan Oral
  • , Krit Jongnarangsin
  • , Frank Pelosi
  • , Fred Morady
  • , Frank Bogun
  • University of Michigan Health System

Research output: Contribution to journalArticlepeer-review

28 Citations (Scopus)

Abstract

Background: Pace mapping is used to identify critical areas for postinfarction ventricular tachycardia (VT). Unexcitable scar during pacing with standard output can identify borders of the reentry circuit. Unexcitable scar is not thought to contain surviving muscle fibers critical to the circuit. Due to current-to-load mismatch or a deep seated isthmus, higher power might be required in order to obtain capture. Objective: The purpose of this study was to evaluate the value of high-output pacing in patients with postinfarction VT. Methods: In a consecutive series of 18 patients (15 men, age 62 ± 9, EF 0.29 ± 0.15) with postinfarction VT, a voltage map was obtained and bipolar pace mapping was performed in areas with low voltage (<1.5 mV) at an output of 10 mA and 2 ms pulse width (PW). High-output capture was defined as capture that failed at these settings but succeeded at higher pacing output. The pacing output was increased to 20 mA at 2 ms, and the PW was increased to 10 ms as required to achieve capture. Results: Seventy-seven VTs were induced. Thirty-nine isthmus sites were identified. Focal areas with high-output capture were observed in 12/18 patients (output: 20 mA; mean PW: 7.3 ± 3.5 ms). In 9/18 patients, this area was critical for the reentry circuit of 10 clinical VTs (23% of isthmus sites). In one third of patients, isthmus sites were identified only by high-output pacing. Conclusion: High-output pacing can be helpful in identifying critical areas of postinfarction VT that otherwise may be missed.

Original languageEnglish
Pages (from-to)1709-1714
Number of pages6
JournalHeart Rhythm
Volume5
Issue number12
DOIs
Publication statusPublished - Dec 2008
Externally publishedYes

Keywords

  • Catheter ablation
  • Mapping
  • Myocardial infarction
  • Pacing
  • Tachycardia

Fingerprint

Dive into the research topics of 'High-output pacing in mapping of postinfarction ventricular tachycardia'. Together they form a unique fingerprint.

Cite this