Skip to main navigation Skip to search Skip to main content

Field comparison of BG-Pro configurations with CDC light traps and evaluation of the BG-Counter 2 trap for automated mosquito surveillance in urban and rural Thailand

  • Faculty of Tropical Medicine, Mahidol University
  • Biogents AG
  • University of Bremen

Research output: Contribution to journal › Article › peer-review

Abstract

Background: Entomological surveillance programmes need traps that perform reliably across vector taxa and ecological settings, and automated tools that reduce labour without compromising data quality. We evaluated BG-Pro trap configurations and the BG-Counter 2 against the standard CDC light trap (CDC-LT) across contrasting urban and rural ecologies in Thailand. Methods: We compared CDC light traps (CDC-LT) baited with CO₂, BG-Pro traps (BG-Lure + CO₂), and inverted BG-Pro traps (BG-Lure + CO₂) using a 3 × 3 Latin square design over 270 trap-days across two urban sites (Bangkok and Nakhon Pathom; Nov 2024–Mar 2025) and one rural malaria-endemic site (Tha Song Yang, Tak; Jul — Oct 2024). Trap performance was analysed using generalized linear mixed models (GLMMs) to estimate incidence rate ratios (IRRs). The BG-Counter 2 accuracy was assessed over 60 trap-days by comparing automated with manual counts. Results: A total of 54,054 mosquitoes representing six genera were collected, dominated by Culex (77.6%). Across sites, BG-Pro produced the highest overall catches (urban mean 946.04; rural mean 13.29 mosquitoes/trap-day) and outperformed CDC-LT in both urban (IRR = 6.11) and rural (IRR = 2.64) settings, while the inverted BG-Pro traps captured the fewest mosquitoes. Genus-specific patterns were consistent across ecological settings: BG-Pro achieved the highest mean capture rates for Aedes (urban 8.3; rural 1.4 mosquitoes/trap-day) and Culex (urban 936.3; rural 8.3 mosquitoes/trap-day), indicating stronger performance for culicines relative to CDC-LT. In the rural site, overall captures of Anopheles minimus were very low across all traps, while CDC-LT sampled a broader range of anopheline taxa. The BG-Counter 2 median accuracy was high in urban sites (89.0%) but low in the rural site (20.6%), with the sensor overcounting mosquitoes on the majority of trap-days in both settings. Conclusions: No single trap optimally samples all vector groups across ecological settings. BG-Pro (BG-Lure + CO₂) showed promising utility for operational culicine surveillance in urban Thailand, whereas CDC-LT remains preferable for anopheline monitoring in rural malaria-risk settings. The BG-Counter 2 can support near-real-time trend monitoring in low-background urban environments but requires site-specific calibration before rural deployment. These findings support a context-specific surveillance strategy that combines complementary traps rather than relying on a single platform.

Original languageEnglish
Article number343
JournalParasites and Vectors
Volume19
Issue number1
DOIs
Publication statusPublished - Dec 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Automatic counting
  • Mosquito trap
  • Mosquito-borne diseases
  • Surveillance system
  • Trapping efficacy

Fingerprint

Dive into the research topics of 'Field comparison of BG-Pro configurations with CDC light traps and evaluation of the BG-Counter 2 trap for automated mosquito surveillance in urban and rural Thailand'. Together they form a unique fingerprint.

Cite this