Skip to main navigation Skip to search Skip to main content

Enhancing accuracy and adherence in blood pressure monitoring in living kidney donation: implementing technologies to overcome challenges

  • Ekamol Tantisattamo
  • , Manoch Rattanasompattikul
  • , Opas Traitanon
  • , Natsuki Eguchi
  • , Hirohito Ichii
  • , Surasak Kantachuvesiri
  • , Kamyar Kalantar-Zadeh
  • University of California Irvine Medical Center
  • VA Healthcare Long Beach
  • Oakland University William Beaumont School of Medicine
  • Pacific Northwest University of Health Sciences
  • Faculty of Medicine Ramathibodi Hospital, Mahidol University
  • Siriraj Hospital
  • Thammasat University
  • Thammasat University Hospital
  • University of California
  • University of Arizona College of Medicine – Phoenix
  • Los Angeles Biomedical Research Institute

Research output: Contribution to journal › Article › peer-review

Abstract

Purpose of review – Blood pressure (BP) monitoring is crucial to detect and manage postdonation hypertension early; however, obtaining accurate BP readings and regular BP monitoring remains challenging.Recent findings – While office BP (OBP) measurement is almost universal, implementing accurate OBP readings by utilizing automatic office BP (AOBP) can be challenging due to its time-consuming. Moreover, OBP cannot be performed regularly, especially in a telemedicine setting. Out-of-office BP (OOOBP) can overcome the challenges in obtaining accurate OBP readings and monitoring BP. While 24-h ambulatory BP monitoring remains the gold standard for diagnosing hypertension in living kidney donors (LKDs), its availability is limited. Since OOOBP relies on the patients’ BP measurement technique, technologies can help facilitate and enable LKD to check their BP accurately and regularly, including self-measured BP monitoring (SMBPM) and automatic remote BP monitoring. Cuffless BP monitoring offers convenience to the patients; further validation is required. Utilizing technologies for BP measurement is a proposed intervention to increase adherence to BP measurement and monitoring.Summary – While several BP measurement modalities can provide accurate BP readings, some facilitate better accuracy, especially unattended BP measurements and should be implemented for BP monitoring to mitigate cardiovascular outcomes in LKD.

Original languageEnglish
Pages (from-to)43-51
Number of pages9
JournalCurrent Opinion in Nephrology and Hypertension
Volume35
Issue number1
DOIs
Publication statusPublished - Jan 2026

Keywords

  • automatic office blood pressure monitoring
  • automatic remote blood pressure monitoring
  • cuffless blood pressure monitoring
  • home blood pressure
  • implementation research and practice

Fingerprint

Dive into the research topics of 'Enhancing accuracy and adherence in blood pressure monitoring in living kidney donation: implementing technologies to overcome challenges'. Together they form a unique fingerprint.

Cite this