Skip to main navigation Skip to search Skip to main content

Electrochemical Sensor Based on a Composite of Reduced Graphene Oxide and Molecularly Imprinted Copolymer of Polyaniline−Poly(o‑phenylenediamine) for Ciprofloxacin Determination: Fabrication, Characterization, and Performance Evaluation

  • Suwanna Kitpati Boontanon
  • , Jedsada Chuiprasert
  • , Sira Srinives
  • , Narin Boontanon
  • , Chongrak Polprasert
  • , Nudjarin Ramungul
  • , Napat Lertthanaphol
  • , Apisit Karawek
  • Graduate School of Global Environmental Studies
  • Mahidol University
  • Thammasat University
  • Thailand Science Park

Research output: Contribution to journalArticlepeer-review

46 Citations (Scopus)

Abstract

Contamination of antibiotics in water is a major cause of antibiotic resistance (ABR) in pathogens that endangers human health and food security worldwide. Ciprofloxacin (CIP) is a synthetic fluoroquinolone (FQ) antibiotic and is reportedly present in surface water at a concentration exceeding the ecotoxicological predicted no-effect concentration in some areas. This study fabricated a CIP sensor using an electropolymerized molecularly imprinted polymer (MIP) of polyaniline (PANI) and poly(o-phenylenediamine) (o-PDA) with CIP recognition sites. The MIP was coated on a reduced graphene oxide (rGO)modified glassy carbon electrode (rGO/GCE) and operated under a differential pulse voltammetry (DPV) mode for CIP detection. The sensor exhibited an excellent response from 1.0 × 10−9 to 5.0 × 10−7 mol L−1 CIP, showing a sensor detection limit and sensitivity of 5.28 × 10−11 mol L−1 and 5.78 μA mol−1 L, respectively. The sensor’s sensitivity for CIP was 1.5 times higher than that of the other tested antibiotics, including enrofloxacin (ENR), ofloxacin (OFX), sulfamethoxazole (SMZ), and piperacillin sodium salt (PIP). The reproducibility and reusability of the sensor devices were also studied. [Figure presented].

Original languageEnglish
Pages (from-to)2564-2574
Number of pages11
JournalACS Omega
Volume8
Issue number2
DOIs
Publication statusPublished - 17 Jan 2023

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 2 - Zero Hunger
    SDG 2 Zero Hunger

Fingerprint

Dive into the research topics of 'Electrochemical Sensor Based on a Composite of Reduced Graphene Oxide and Molecularly Imprinted Copolymer of Polyaniline−Poly(o‑phenylenediamine) for Ciprofloxacin Determination: Fabrication, Characterization, and Performance Evaluation'. Together they form a unique fingerprint.

Cite this