Skip to main navigation Skip to search Skip to main content

Dynamic arterial elastance for predicting mean arterial pressure responsiveness after fluid challenges in acute respiratory distress syndrome patients

  • Ramathibodi Hospital

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

Background: Blood pressure is controlled by stroke volume and afterload. Arterial load is an effective measure of afterload because it represents all extracardiac factors that oppose left ventricular ejection. Dynamic arterial elastance (Eadyn; pulse pressure variation over stroke volume variation) is a dynamic parameter of arterial load that can be continuously monitored. Eadyn was reported to predict mean arterial pressure (MAP) responsiveness after a fluid challenge. Objective: To assess whether Eadyn can predict MAP responsiveness in acute respiratory distress syndrome (ARDS) patients ventilated with low tidal volume. Materials and Methods: The authors performed a prospective study of diagnostic test accuracy in adult ARDS patients with acute circulatory failure and fluid responsiveness. All patients received continuous blood pressure monitoring via an arterial line connected to a Flotrac™ transducer and Vigileo™ monitor. When the attending physicians decided to load intravenous fluid, the authors recorded the pulse pressure variation over stroke volume variation and other hemodynamic parameters before and after fluid bolus. MAP responsiveness was defined as increased MAP of 10% or more from baseline after fluid challenge. Results: Twenty-three events were included. Nine events (39.13%) were MAP-responsive. Cardiac output, heart rate, and stroke volume were similar in both MAP-responder and MAP-non-responder groups. Baseline MAP, diastolic blood pressure, and pulse pressure were significantly different after fluid challenge in the MAP-responder group. Eadyn of the pre-infusion phase failed to predict MAP responsiveness after fluid challenge (area under the curve 0.603, 95% confidence interval 0.38 to 0.798). Conclusion: Arterial load parameters, including Eadyn, derived from non-calibrated pulse contour analysis failed to predict MAP responsiveness in ARDS patients with low tidal volume ventilation.

Original languageEnglish
Pages (from-to)646-651
Number of pages6
JournalJournal of the Medical Association of Thailand
Volume103
Issue number7
DOIs
Publication statusPublished - Jul 2020

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Acute respiratory distress syndrome
  • Dynamic arterial elastance
  • Mean arterial pressure
  • Pulse contour analysis

Fingerprint

Dive into the research topics of 'Dynamic arterial elastance for predicting mean arterial pressure responsiveness after fluid challenges in acute respiratory distress syndrome patients'. Together they form a unique fingerprint.

Cite this