Skip to main navigation Skip to search Skip to main content

Does Implant Density Impact Three-Dimensional Deformity Correction in Adolescent Idiopathic Scoliosis with Lenke 1 and 2 Curves Treated by Posterior Spinal Fusion without Ponte Osteotomies?

  • VA Medical Center
  • Cincinnati Children’s Hospital Medical Center

Research output: Contribution to journal › Article › peer-review

12 Citations (Scopus)

Abstract

Study Design: Retrospective cohort study. Purpose: To determine whether implant density impact three-dimensional deformity correction in posterior spinal fusion (PSF) without Ponte osteotomies (POs) for patients with Lenke 1 and 2 adolescent idiopathic scoliosis (AIS). Overview of Literature: Currently, the optimal pedicle screw (PS) density for flexible moderate-sized thoracic AIS curve correction is still controversial. There are limited data regarding the impact of implant density on three-dimensional correction in PSF without the use of PO for thoracic AIS surgery. Methods: A database of patients with AIS with Lenke 1 and 2 curves treated with PSF without PO and instrumented with PSs and ≥2-year follow-up was reviewed. The preoperative, immediate, and final follow-up postoperative radiographs were analyzed. The correlation between PS density and the following factors were determined: major curve correction (MCC), correction index (CI; MCC/ curve flexibility), kyphosis angle change, and rib index (RI) correction. Then, patients were divided into low-density (LD) and highdensity (HD) groups according to mean PS density for the entire cohort (1.5 PS per level). Demographics and radiographic and clinical outcomes were compared between groups. Results: The study included 99 patients with Lenke 1 and 23 patients with Lenke 2 AIS. The average MCC was 67.2%. There was no correlation between screw density and these parameters: MCC (r =0.10, p =0.26), CI (r =0.16, p =0.07), change in T2–T12 kyphosis angle (r =−0.13, p =0.14), and RI correction (r =−0.09, p =0.37). Demographic and preoperative radiographic parameters were similar between the LD and HD groups. At the latest follow-up, there were no differences between the two groups in regard to MCC, CI, change in T2–T12 kyphosis angle, RI correction, and Scoliosis Research Society-30 scores (all p >0.05). Conclusions: This study revealed no significant correlation between screw density and curve correction in any planes.

Original languageEnglish
Pages (from-to)375-385
Number of pages11
JournalAsian Spine Journal
Volume16
Issue number3
DOIs
Publication statusPublished - Jun 2022

Keywords

  • Adolescent idiopathic scoliosis
  • Curve correction
  • Implant density
  • Pedicle screws

Fingerprint

Dive into the research topics of 'Does Implant Density Impact Three-Dimensional Deformity Correction in Adolescent Idiopathic Scoliosis with Lenke 1 and 2 Curves Treated by Posterior Spinal Fusion without Ponte Osteotomies?'. Together they form a unique fingerprint.

Cite this