Skip to main navigation Skip to search Skip to main content

Detection of restenosis after percutaneous transluminal coronary angioplasty using the exercise treadmill test and technetium 99m-sestamibi scintigraphy

  • Suphot Srimahachota
  • , Smonporn Boonyaratavej
  • , Wasan Udayachalerm
  • , Peungchai Ngarmukos
  • , Todsapol Limpijankit
  • , Supattaraporn Tepmongkol
  • , Taworn Suithichaiyakul
  • Faculty of Medicine, Chulalongkorn University
  • King Chulalongkorn Memorial Hospital

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

Background: The detection of myocardial ischemia after percutaneous transluminal coronary angioplasty (PTCA) is important because 30-50 per cent of the patients will develop restenosis within 6 months. Symptoms of chest pain and exercise stress test (EST) have shown to be less sensitive for detection of ischemia than exercise Technetium-99m Sestamibi (Tc-99m MIBI). The purpose of this study was to compare the sensitivity and specificity of chest pain, EST and Tc-99m MIBI with coronary angiography (CAG). Method: Tc-99m MIBI with SPECT imaging was performed at months l, 3 and 6 and CAG was repeated 6 months after successful PTCA. Earlier Tc-99m MIBI and CAG were performed in patients with recurrent angina pectoris or suspected restenosis. Results : Forty six patients (M 29, F 17) who had undergone successful angioplasty were prospectively enrolled. Their mean age was 61 ± 19 yrs. Eighty eight lesions (LAD63%, LCX34%, RCA19%) were performed. Lesion characteristics were type A in 9 per cent, type in B 30 per cent and type C in 61 per cent. Fifty four per cent of PTCA were performed for single vessel disease and 46 per cent for multivessel disease. The mean duration of time between PTCA and follow-up CAG was 6.1 ± 2.7 months. We detected restenosis from CAG in 58 per cent of the cases. The Tc-99m MIBI had higher sensitivity to detect restenosis than anginal pain (85.0% vs 39.4% p < 0.005) or EST (85.0% vs 63.6% p < 0.05) when compared with CAG. The overall accuracy of Tc-99m MIBI for the detection of restenosis was 80 per cent. Conclusion: Tc-99m MIBI with SPECT imaging constitutes a better means than symptoms or exercise test to detect restenosis after successful coronary angioplasty.

Original languageEnglish
Pages (from-to)307-313
Number of pages7
JournalJournal of the Medical Association of Thailand
Volume84
Issue number3
Publication statusPublished - Mar 2001
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Coronary Angioplasty
  • Restenosis
  • Technetium-99m Sestamibi

Fingerprint

Dive into the research topics of 'Detection of restenosis after percutaneous transluminal coronary angioplasty using the exercise treadmill test and technetium 99m-sestamibi scintigraphy'. Together they form a unique fingerprint.

Cite this