Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer

  • Siriraj Hospital

Research output: Contribution to journal › Article › peer-review

175 Citations (Scopus)

Abstract

Purpose To evaluate the repeatability and reproducibility of a newer swept-source optical biometer and to compare it with a standard partial coherence interferometry (PCI) biometer. Setting Siriraj Hospital, Mahidol University, Bangkok, Thailand. Design Prospective comparative study. Methods One hundred eyes from 100 cataract patients were enrolled in this study. Each patient was measured with 2 optical biometers, a newer swept-source optical biometer (IOLMaster 700) and a standard partial coherence interferometry biometer (IOLMaster 500) by 2 independent operators. The keratometry, axial length (AL), anterior chamber depth, white-to-white corneal diameter, and intraocular lens (IOL) power, calculated by the SRK/T and the Haigis formulas for each device, were recorded. Intraoperator repeatability and interoperator reproducibility of both devices were analyzed using intraclass correlation coefficients (ICCs). Agreement of ocular biometry and IOL power between the 2 devices was evaluated using the Bland-Altman method. Results The repeatability and reproducibility of the swept-source and standard biometers were high for all ocular biometry parameters (ICC, 0.93-1.00). The agreement between the 2 biometers was also high (ICC, 0.92-1.00). The IOL powers obtained from both devices were not distinct. Because of the density of the cataracts, the AL in 5 eyes could be measured only by the swept-source biometer. Conclusions Repeatability and reproducibility of a swept-source optical biometer was excellent and agreement with a standard biometer was very high. Better lens penetration ability and AL measurements were obtained with the swept-source biometer than with the standard biometer. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.

Original languageEnglish
Pages (from-to)2224-2232
Number of pages9
JournalJournal of Cataract and Refractive Surgery
Volume41
Issue number10
DOIs
Publication statusPublished - 1 Oct 2015

Fingerprint

Dive into the research topics of 'Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer'. Together they form a unique fingerprint.

Cite this