Skip to main navigation Skip to search Skip to main content

Characteristics of atrial tachycardia due to small vs large reentrant circuits after ablation of persistent atrial fibrillation

  • Miki Yokokawa
  • , Rakesh Latchamsetty
  • , Hamid Ghanbari
  • , Diego Belardi
  • , Akash Makkar
  • , Brett Roberts
  • , Wouter Saint-Phard
  • , Mohamad Sinno
  • , Thomas Carrigan
  • , Robert Kennedy
  • , Arisara Suwanagool
  • , Eric Good
  • , Thomas Crawford
  • , Krit Jongnarangsin
  • , Frank Pelosi
  • , Frank Bogun
  • , Hakan Oral
  • , Fred Morady
  • , Aman Chugh
  • University of Michigan Medical School

Research output: Contribution to journalArticlepeer-review

46 Citations (Scopus)

Abstract

Background: While macroreentrant atrial tachycardias (ATs) have been reasonably well described, little is known about small reentrant circuits. Objective: To compare characteristics of large and small reentrant circuits after ablation of persistent atrial fibrillation. Methods: Seventy-seven patients (age 61±10 years; left atrium 46±6 mm; ejection fraction 0.52±0.13) underwent a procedure for postablation AT. The p-wave duration, circuit size, electrogram characteristics, and conduction velocity were determined. Results: AT was due to macroreentry in 62 (80%) patients, a small reentrant circuit in 13 (17%), and a focal mechanism in 2 (3%). The p-wave duration during small reentrant ATs was shorter than that during macroreentry (174±12 ms vs 226±22 ms; P<.0001). The duration of fractionated electrograms at the critical site was longer in small vs large circuits (167±43 ms vs 98±38 ms, respectively; P<.0001) and accounted for a greater percentage of the tachycardia cycle length (59%±18% vs 38%±14%, respectively; P<.0001). The mean diameters of macroreentrant and small reentrant circuits were 44±7 and 26±11 mm, respectively (P<.0001). The mean conduction velocity along the small circuits was lower (0.5±0.2 m/s vs 1.2±0.3 m/s; P<.0001). Catheter ablation eliminated the AT in all 77 patients. Conclusions: AT due to a small reentrant circuit after ablation of atrial fibrillation may be distinguished from macroreentry by a shorter p-wave duration and the presence of long-duration electrograms at the critical site owing to extremely slow conduction. These features may aid the clinician in the mapping of postablation ATs.

Original languageEnglish
Pages (from-to)469-476
Number of pages8
JournalHeart Rhythm
Volume10
Issue number4
DOIs
Publication statusPublished - Apr 2013
Externally publishedYes

Keywords

  • Atrial fibrillation
  • Atrial tachycardia
  • Catheter ablation
  • Linear ablation
  • Proarrhythmia

Fingerprint

Dive into the research topics of 'Characteristics of atrial tachycardia due to small vs large reentrant circuits after ablation of persistent atrial fibrillation'. Together they form a unique fingerprint.

Cite this