Skip to main navigation Skip to search Skip to main content

Asia Pacific Heart Rhythm Society (APHRS) scientific statement on stroke prevention strategies in patients with device-detected atrial fibrillation: the 4S-DDAF approach

  • Tze Fan Chao
  • , Chu Pak Lau
  • , Eue Keun Choi
  • , Chi Keong Ching
  • , Ngai Yin Chan
  • , Chung Lieh Hung
  • , Boyoung Joung
  • , Rungroj Krittayaphong
  • , Hung Fat Tse
  • , Gregory Y.H. Lip
  • Taipei Veterans General Hospital
  • Taipei Veterans General Hospital and National Yang-Ming Chiao Tung University
  • University of Hong Kong
  • Seoul National University Hospital
  • Seoul National University College of Medicine
  • National Heart Center
  • Princess Margaret Hospital Hong Kong
  • MacKay Memorial Hospital
  • Mackay Medical College
  • Yonsei University College of Medicine
  • University of Liverpool
  • Aalborg University
  • Medical University of Bialystok

Research output: Contribution to journal › Review article › peer-review

3 Citations (Scopus)

Abstract

Device-detected atrial fibrillation (DDAF), including atrial high-rate episodes recorded at a cardiovascular implantable electronic device and subclinical atrial fibrillation detected by insertable cardiac monitor and smart wearables, poses an increasing challenge in stroke prevention. Although oral anticoagulants (OACs) are effective in clinical AF, their benefit-risk balance in DDAF remains uncertain. In response, the Asia Pacific Heart Rhythm Society (APHRS) proposes the 4S-DDAF approach (Strip documentation and longest AF duration, Symptoms, Stroke [ischemic] history, and Score) to guide anticoagulation decisions. This approach integrates electrogram review, symptom assessment, history of ischemic stroke or transient ischemic attack (TIA), and CHA2DS2-VASc scoring, emphasizing individualized care. OACs are recommended for patients with AF episodes ≥24 h, prior stroke/TIA, CHA2DS2-VASc score ≥4, or vascular disease. In patients not meeting these thresholds, close monitoring and risk factor management are advised. The 4S-DDAF approach provides a practical and evidence-informed strategy for clinical decision-making in the management of DDAF.

Original languageEnglish
Article number101770
JournalThe Lancet Regional Health - Western Pacific
Volume65
DOIs
Publication statusPublished - Dec 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • 4S-DDAF approach
  • APHRS
  • Atrial high-rate episodes
  • Device-detected atrial fibrillation
  • Subclinical atrial fibrillation

Fingerprint

Dive into the research topics of 'Asia Pacific Heart Rhythm Society (APHRS) scientific statement on stroke prevention strategies in patients with device-detected atrial fibrillation: the 4S-DDAF approach'. Together they form a unique fingerprint.

Cite this