TY - GEN
T1 - An investigation on moisture and water absorption in cement paste with electrical resistance method
AU - Mizoguchi, M.
AU - Kitagawa, T.
AU - Daungwilailuk, T.
AU - Ogawa, Y.
AU - Kawai, K.
N1 - Publisher Copyright:
© ICDCS 2018. All rights reserved.
PY - 2018
Y1 - 2018
N2 - Moisture in concrete is one of main factors related to degradation and deterioration of concrete structure, and there are various moisture transport phenomena in concrete such as drying and absorbing. There are a lot of previous studies on the drying process of concrete to clarify the mechanisms of creep as well as shrinkage. However, few studies have been reported on the process of water absorption and moisture absorption although carbonation and chloride attack are strongly related to moisture and water absorbing. It is necessary to investigate moisture transfer in concrete in detail. This study investigated the moisture transfer in moisture and water absorbing processes in cement paste by using electrical resistance method to understand how moisture and water transfer into concrete. Cement paste specimens with water-to-cement ratios (W/Cs) of 0.35 and 0.55 were prepared in this study. Stainless steel rods of 0.9 mm in diameter were arranged at an interval of 4 mm in the specimen for measuring the electrical resistance. The specimens for moisture and water absorbing test were cured in water at 20 °C for 28 days and stored at 20 °C and a relative humidity of 0% and 70% as reference and the national average of the annual average relative humidity in Japan, respectively. The electrical resistances were measured through the stainless-steel rods and converted to electrical resistivity. The calibration test was also conducted to obtain the relationship between the electrical resistivity and the internal relative humidity (IRH), which was used to know IRH in cement paste specimen. As a result, the rate of moisture transfer in the specimen at initial internal relative humidity (IIRH) of 0% was higher than that at IIRH of 70%. Additionally, the rate of moisture transfer in the specimen at any IIRH depends on the total pore volume in the specimen.
AB - Moisture in concrete is one of main factors related to degradation and deterioration of concrete structure, and there are various moisture transport phenomena in concrete such as drying and absorbing. There are a lot of previous studies on the drying process of concrete to clarify the mechanisms of creep as well as shrinkage. However, few studies have been reported on the process of water absorption and moisture absorption although carbonation and chloride attack are strongly related to moisture and water absorbing. It is necessary to investigate moisture transfer in concrete in detail. This study investigated the moisture transfer in moisture and water absorbing processes in cement paste by using electrical resistance method to understand how moisture and water transfer into concrete. Cement paste specimens with water-to-cement ratios (W/Cs) of 0.35 and 0.55 were prepared in this study. Stainless steel rods of 0.9 mm in diameter were arranged at an interval of 4 mm in the specimen for measuring the electrical resistance. The specimens for moisture and water absorbing test were cured in water at 20 °C for 28 days and stored at 20 °C and a relative humidity of 0% and 70% as reference and the national average of the annual average relative humidity in Japan, respectively. The electrical resistances were measured through the stainless-steel rods and converted to electrical resistivity. The calibration test was also conducted to obtain the relationship between the electrical resistivity and the internal relative humidity (IRH), which was used to know IRH in cement paste specimen. As a result, the rate of moisture transfer in the specimen at initial internal relative humidity (IIRH) of 0% was higher than that at IIRH of 70%. Additionally, the rate of moisture transfer in the specimen at any IIRH depends on the total pore volume in the specimen.
KW - Cement paste
KW - Durability
KW - Electrical resistance
KW - Moisture transfer
UR - https://www.scopus.com/pages/publications/85079100418
M3 - Conference contribution
AN - SCOPUS:85079100418
T3 - 6th International Conference on Durability of Concrete Structures, ICDCS 2018
SP - 581
EP - 586
BT - 6th International Conference on Durability of Concrete Structures, ICDCS 2018
A2 - Basheer, P. A. Muhammed
PB - Whittles Publishing Limited
T2 - 6th International Conference on Durability of Concrete Structures, ICDCS 2018
Y2 - 18 July 2018 through 20 July 2018
ER -