Skip to main navigation Skip to search Skip to main content

Absolute calibration of LHAASO WFCTA camera based on LED

  • LHAASO Collaboration
  • Dublin Institute for Advanced Studies
  • Max-Planck-Institut for Nuclear Physics
  • State Key Laboratory of Particle Detection and Electronics
  • University of Science and Technology of China
  • Southwest Jiaotong University
  • Sichuan University
  • Institute of High Energy Physics, Chinese Academy of Sciences
  • TIANFU Cosmic Ray Research Center
  • Nanjing University
  • Guangzhou University
  • University of Chinese Academy of Sciences
  • Wuhan University
  • Purple Mountain Observatory Chinese Academy of Sciences
  • Hebei Normal University
  • Shanghai Astronomical Observatory Chinese Academy of Sciences
  • Key Laboratory of Cosmic Rays (Tibet University)
  • National Astronomical Observatories Chinese Academy of Sciences
  • Sun Yat-Sen University
  • Yunnan University
  • Université de Genève
  • Complesso Universitario di Monte S. Angelo
  • Shandong University
  • Mahidol University
  • National Institute of Metrology China
  • Tsinghua University
  • Zhengzhou University
  • Institute for Nuclear Research of the Russian Academy of Sciences
  • Peking University
  • Guangxi University
  • Shanghai Jiao Tong University
  • Yunnan Observatories
  • Moscow Institute of Physics and Technology
  • National Space Science Center

Research output: Contribution to journal › Article › peer-review

24 Citations (Scopus)

Abstract

The main scientific goal of the LHAASO WFCTA experiment is to measure the cosmic ray energy spectra and composition from 10 TeV to 1 EeV. Cherenkov photons in the extensive air shower measured by the SiPM camera of Cherenkov telescopes can be used to reconstruct the cosmic ray energy. The absolute calibration of the camera is a crucial step to achieve the accurate measurement of the cosmic ray energy spectrum. A multi-wavelength cylindrical illuminator based on LEDs is developed and mounted inside the telescope to calibrate and monitor the camera, and the illuminator's stability is better than 0.5% under the temperature variation from -26 to 26 °C. A portable probe with a single photoelectron resolution of 21.6% is developed. After calibration by National Institute of Metrology, China (NIM), the probe is taken to the LHAASO site to measure the absolute photon density of the cylindrical illuminator inside the telescope. Based on the illuminator with known photon density, the photon conversion factor of the camera can be calibrated, and the overall calibration uncertainty is less than 2.6%.

Original languageEnglish
Article number165824
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume1021
DOIs
Publication statusPublished - 1 Jan 2022
Externally publishedYes

Keywords

  • Calibration
  • Cylindrical illuminator
  • LHAASO-WFCTA
  • Photons to electronic signal
  • Relative photon distribution
  • SiPM camera

Fingerprint

Dive into the research topics of 'Absolute calibration of LHAASO WFCTA camera based on LED'. Together they form a unique fingerprint.

Cite this