OBJECTIVE: To compare sensitivity, specificity, accuracy and diagnostic confidence in the differentiation between benign and metastatic bone lesions on whole body planar bone scintigraphy and Evolution SPECT/CT.

MATERIAL AND METHOD: Eighty diagnosed or suspected cancer patients with indeterminate lesions on planar scintigraphy were recruited in the present prospective study. Additional whole body Evolution SPECT/CT was performed after whole body planar scintigraphy. All lesions on both imagings were categorized into 5 categories; definitely metastasis, probably metastasis, indeterminate, probably benign and definitely benign. The diagnosis of each lesion was confirmed by follow-up imaging, pathological findings or clinical follow-up for at least 6 months.

RESULTS: Detected lesions on planar scintigraphy and Evolution SPECT/CT imaging were 442 and 477 lesions, respectively.The sensitivity, specificity and accuracy of planar scintigraphy and Evolution SPECT/CT imaging in the diagnosis of metastatic lesions were 27% (95% CI: 13.8, 44.1), 63.2% (95% CI: 58.5, 67.7), 60%, and 97.3% (95% CI: 85.8, 99.9), 100% (95% CI: 96.4, 100) and 99.8%, respectively. Indeterminate lesions on planar scintigraphy were 34.2% (151 lesions from total 442 lesions, which 135 of these 151 indeterminate lesions or 89.4% were located in axial skeleton). Evolution SPECT/CT images were able to characterize all indeterminate lesions.

CONCLUSION: Differentiation of benign and metastatic lesions by Evolution SPECT/CT images has superior diagnostic performance and diagnostic confidence over the planar scintigraphy. Thus, Evolution SPECT/CT images should be considered in characterization of indeterminate lesions on planar scintigraphy, especially in the axial skeleton.

Original languageEnglish
Pages (from-to)100-10
Number of pages11
JournalJournal of the Medical Association of Thailand
Volume100
Issue number1
Publication statusPublished - Jan 2017

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Adult
  • Aged
  • Aged, 80 and over
  • Bone Neoplasms/diagnostic imaging
  • Bone and Bones/diagnostic imaging
  • Diagnosis, Differential
  • Female
  • Humans
  • Image Processing, Computer-Assisted/methods
  • Male
  • Middle Aged
  • Multimodal Imaging/methods
  • Prospective Studies
  • Radionuclide Imaging/methods
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, Emission-Computed, Single-Photon/methods
  • Tomography, X-Ray Computed/methods
  • Whole Body Imaging/methods
  • Young Adult

Fingerprint

Dive into the research topics of 'A Comparison of Accuracy of Planar and Evolution SPECT/CT Bone Imaging in Differentiating Benign from Metastatic Bone Lesions'. Together they form a unique fingerprint.

Cite this