TY - GEN
T1 - 3D extraction using DLT with one camera
AU - Adhan, Suchin
AU - Pintavirooj, Chuchart
AU - Sanpanich, Arthorn
PY - 2013
Y1 - 2013
N2 - This paper proposes a method for accurate measurement of a three-dimensional of an eye's pupil by combining local stereo images which are acquired from multiway. A calibrated mini CCD camera is used to capture the side-by-side image of one eye by two plane mirrors to create a reflection of the two directions of the eye at a time. The center of mass is used for two-dimensional coordinates of the center of the pupil. The new and simple technique to solve the problem of geometric distortion is proposed by taking advantage of the Direct Linear Transformation (DLT), which requires only a single step in the refinement stage without changing or reinstalling a camera. The DLT algorithm was used for the three-dimensional coordinates of the center of the pupils from the previous two-dimensional coordinates for the three-dimensional position of the eyes is detected. The results are the statistical errors only slight, mean = 0.16°, S.D. = 0.15°, which shows that the system is suitable for high-precision medical applications for the movement of the human eye.
AB - This paper proposes a method for accurate measurement of a three-dimensional of an eye's pupil by combining local stereo images which are acquired from multiway. A calibrated mini CCD camera is used to capture the side-by-side image of one eye by two plane mirrors to create a reflection of the two directions of the eye at a time. The center of mass is used for two-dimensional coordinates of the center of the pupil. The new and simple technique to solve the problem of geometric distortion is proposed by taking advantage of the Direct Linear Transformation (DLT), which requires only a single step in the refinement stage without changing or reinstalling a camera. The DLT algorithm was used for the three-dimensional coordinates of the center of the pupils from the previous two-dimensional coordinates for the three-dimensional position of the eyes is detected. The results are the statistical errors only slight, mean = 0.16°, S.D. = 0.15°, which shows that the system is suitable for high-precision medical applications for the movement of the human eye.
KW - 3D Extraction
KW - Direct Linear Transformation
UR - https://www.scopus.com/pages/publications/84893279585
U2 - 10.1109/BMEiCon.2013.6687685
DO - 10.1109/BMEiCon.2013.6687685
M3 - Conference contribution
AN - SCOPUS:84893279585
SN - 9781479914678
T3 - BMEiCON 2013 - 6th Biomedical Engineering International Conference
BT - BMEiCON 2013 - 6th Biomedical Engineering International Conference
T2 - 6th Biomedical Engineering International Conference, BMEiCON 2013
Y2 - 23 October 2013 through 25 October 2013
ER -