TY - GEN
T1 - 2D ultrasonic reflection tomography by linear array transducer and wave reflector
AU - Sanpanich, A.
AU - Hamamoto, K.
AU - Sangworasil, M.
AU - Pintavirooj, C.
PY - 2009
Y1 - 2009
N2 - In general, it was known that when the series of an ultrasonic broadband pulse travel through living organ or soft tissue, their reflected projection data can be used to reconstruct a novel tomographic image. Whereas, a data obtain from an ultrasonic tomography in transmission mode is not able to be used for reconstruction a characteristic image of soft tissue which naturally shadowed by a bone or hard tissue. An ultrasonic tomography in reflection mode is realized to be a solution for this problem. However the implementation to identify the projection by using an integrated attenuation coefficient of tissue from the pulsed wave ray path in reflection mode is still more complicated. In this paper, we propose a simulation in 2D of a reflection-mode ultrasonic tomographic system by using the linear array transducer and also a frequency centroid shift method to calculate the projection data. The imaging setup system was enhanced by wave reflecting plate in order to increase an echo wave path. The ultrasound wave paths of our simulation system were intend to focus on the fan beam trajectory which is rather close to a real propagation of the ultrasound wave traveling through soft tissue and ART was used finally as an image reconstruction algorithm. The obtained output shows that our system is more practical and possible toward for using in a clinical trial.
AB - In general, it was known that when the series of an ultrasonic broadband pulse travel through living organ or soft tissue, their reflected projection data can be used to reconstruct a novel tomographic image. Whereas, a data obtain from an ultrasonic tomography in transmission mode is not able to be used for reconstruction a characteristic image of soft tissue which naturally shadowed by a bone or hard tissue. An ultrasonic tomography in reflection mode is realized to be a solution for this problem. However the implementation to identify the projection by using an integrated attenuation coefficient of tissue from the pulsed wave ray path in reflection mode is still more complicated. In this paper, we propose a simulation in 2D of a reflection-mode ultrasonic tomographic system by using the linear array transducer and also a frequency centroid shift method to calculate the projection data. The imaging setup system was enhanced by wave reflecting plate in order to increase an echo wave path. The ultrasound wave paths of our simulation system were intend to focus on the fan beam trajectory which is rather close to a real propagation of the ultrasound wave traveling through soft tissue and ART was used finally as an image reconstruction algorithm. The obtained output shows that our system is more practical and possible toward for using in a clinical trial.
KW - ART reconstruction
KW - Ultrasound reflection tomography
KW - Wave reflector
UR - https://www.scopus.com/pages/publications/71049147864
U2 - 10.1109/RIVF.2009.5174606
DO - 10.1109/RIVF.2009.5174606
M3 - Conference contribution
AN - SCOPUS:71049147864
SN - 9781424445684
T3 - 2009 IEEE-RIVF International Conference on Computing and Communication Technologies: Research, Innovation and Vision for the Future, RIVF 2009
BT - 2009 IEEE-RIVF International Conference on Computing and Communication Technologies
T2 - 2009 IEEE-RIVF International Conference on Computing and Communication Technologies: Research, Innovation and Vision for the Future, RIVF 2009
Y2 - 13 July 2009 through 17 July 2009
ER -